ovito.io
This module provides two high-level functions for reading and data files:
- ovito.io.export_file(data, file, format, **params)
Writes data to an output file. See section Data export for an overview.
- Parameters
data – The object to be exported. See available options below.
file (str) – The output file path.
format (str) – The kind of file to write. See available options below.
params – Optional keyword arguments depending on the selected format.
Data to be exported
The following things are acceptable as first argument:
PipelineIf you provide a data pipeline, the dynamically computed output of the pipeline is exported. Since pipelines support evaluation at different animation times, a sequence of frames can be exported by passing the keyword argument
multiple_frames=True, see below.DataCollectionIf you specify a data collection, the static snapshot stored in the collection is exported. Note that it depends on the selected file format which objects from the data collection will be exported.
DataObjectIf you specify a single data object, e.g. a
DataTableorSurfaceMesh, just that one object is exported. The behavior is similar to providing aDataCollectioncontaining a single data object.- None
In this case the output of all data pipelines in the current visualization scene (see
ovito.Scene.pipelineslist) is exported to a single file. This option is only supported for the POV-Ray export format, which stores a full scene description.
Additional keyword parameters, as documented below, let you select the aspects of a dataset to be written to the output file. For instance, for some file formats the
columnskeyword controls the set of particle properties to be saved.Output filename
The parameter file specifies the path of the output file. If the filename ends with the suffix .gz, the output file will be compressed using the zlib library to save disk space (works only for text-based file formats).
If a wildcard “*” character appears in the filename, then one file per animation frame is written and the “*” character is replaced with the frame number. This feature is typically used in conjunction with the
multiple_frames=Trueoption, see below.Output formats
The parameter format selects the kind of file to write:
Format string
Description
"txt/attr"Export global attributes to a text file (see below)
"txt/table"Export a
DataTableto a text file"lammps/dump"LAMMPS text-based dump format
"lammps/data"LAMMPS data format
"imd"IMD format
"vasp"POSCAR format
"xyz"XYZ format
"fhi-aims"FHI-aims format
"gsd/hoomd"GSD format used by the HOOMD simulation code
"netcdf/amber"Binary format for MD data following the AMBER format convention
"vtk/trimesh"ParaView VTK format for exporting
SurfaceMeshobjects"vtk/disloc"ParaView VTK format for exporting
DislocationNetworkobjects"vtk/grid"ParaView VTK format for exporting
VoxelGridobjects"ca""povray"POV-Ray scene format
Depending on the selected output format, additional keyword arguments may be passed to
export_file()as documented in the following sections.File columns
For the output formats lammps/dump, xyz, imd, and netcdf/amber you must specify the set of particle properties to export by providing the
columnskeyword parameter:export_file(pipeline, "output.xyz", "xyz", columns = ["Particle Identifier", "Particle Type", "Position.X", "Position.Y", "Position.Z"])
In case of vector properties, one of the property’s
component_namesmust be appended to the base name, e.g. Position.Z or Atomic Strain.XY. See the list of standard particle properties.Tip
If you are not sure which particle properties are available for export, you can print the list of properties produced by your current data pipeline to the console:
print(pipeline.compute().particles)
Exporting several simulation frames
By default, only the current animation frame (frame 0 by default) is exported. To export a different trajectory frame, pass the
framekeyword parameter to theexport_file()function. Alternatively, you can export all frames of the animation sequence at once by specifyingmultiple_frames=True. More refined control is possible through the keyword argumentsstart_frame,end_frame, andevery_nth_frame.Some file formats such as lammps/dump, xyz, gsd/hoomd or netcdf/amber can store all frames of the exported trajectory in a single output file. For other formats, or if you prefer one file per frame, you must pass a filename pattern to
export_file(). The specified output filename must contain a*wildcard character as in the following example, which will be replaced with the animation frame number during export:export_file(pipeline, "output.*.dump", "lammps/dump", multiple_frames=True)
This is equivalent to an explicit for-loop that exports the frames one by one to a series of files:
for i in range(pipeline.source.num_frames): export_file(pipeline, f"output.{i}.dump", "lammps/dump", frame=i)
Floating-point number precision
For text-based file formats, you can specify the desired formatting precision for floating-point values using the
precisionkeyword parameter. The default output precision is 10 digits; the maximum is 17.LAMMPS atom style
When writing files in the lammps/data format, the LAMMPS atom style “atomic” is used by default. If you want to output a data file with a different LAMMPS atom style, specify it using the
atom_stylekeyword parameter:export_file(pipeline, "output.data", "lammps/data", atom_style="bond") export_file(pipeline, "output.data", "lammps/data", atom_style="hybrid", atom_substyles=("template", "charge"))
If at least one
ParticleTypeof the exported model has a non-zeromassvalue, OVITO writes aMassessection to the LAMMPS data file. You can suppress it by passingomit_masses=Trueto the export function. Furthermore, the keyword argumentignore_identifiers=Truereplaces any existing atom IDs (particle property Particle Identifier) with a contiguous sequence of numbers during file export.VASP (POSCAR) format
When exporting to the vasp file format, OVITO will output atomic positions and velocities in Cartesian coordinates by default. You can request output in reduced cell coordinates by specifying the
reducedkeyword parameter:export_file(pipeline, "structure.poscar", "vasp", reduced=True)
Global attributes
The txt/attr file format allows you to write global quantities computed by the data pipeline to a text file. For example, here is how you export the number of FCC atoms identified by a
CommonNeighborAnalysisModifieras a function of simulation time to a simple text file:export_file(pipeline, "data.txt", "txt/attr", columns=["Timestep", "CommonNeighborAnalysis.counts.FCC"], multiple_frames=True)
Tip
If you are not sure which global attributes are available for export, you can print the list of
attributesproduced by your current data pipeline to the console:print(pipeline.compute().attributes)
- ovito.io.import_file(location, **params)
Imports data from an external file.
This Python function corresponds to the Load File menu command in OVITO’s user interface. The format of the imported file is automatically detected (see list of supported formats). Depending on the file’s format, additional keyword parameters may be required to specify how the data should be interpreted. These keyword parameters are documented below.
- Parameters
location – The file to import. This can be a local file path or a remote sftp:// or https:// URL.
- Returns
The new
Pipelinethat has been created for the imported data.
The function creates and returns a new
Pipelineobject, which uses the contents of the external data file as input. The pipeline will be wired to aFileSource, which reads the input data from the external file and passes it on to the pipeline. You can access the data by calling thePipeline.compute()method or, alternatively,FileSource.compute()on the datasource. As long as the newPipelinecontains no modifiers yet, both methods will return the same data.Note that the
Pipelineis not automatically inserted into the three-dimensional scene. That means the loaded data won’t appear in rendered images or the interactive viewports of OVITO by default. For that to happen, you need to explicitly insert the pipeline into the scene by calling itsadd_to_scene()method if desired.Furthermore, note that you can re-use the returned
Pipelineif you want to load a different data file later on. Instead of callingimport_file()again to load another file, you can use thepipeline.source.load(...)method to replace the input file of the already existing pipeline.File data columns
When importing simple-format XYZ files or legacy binary LAMMPS dump files, the mapping of file columns to particle properties in OVITO must be specified using the
columnskeyword parameter:pipeline = import_file('file.xyz', columns = ['Particle Identifier', 'Particle Type', 'Position.X', 'Position.Y', 'Position.Z'])
The number of column strings must match the actual number of data columns in the input file. See this table for standard particle property names. Alternatively, you can specify user-defined names for file columns that should be read as custom particle properties by OVITO. For vector properties, the component name must be appended to the property’s base name as demonstrated for the
Positionproperty in the example above. To ignore a file column during import, useNoneas entry in thecolumnslist.For LAMMPS dump files or extended-format XYZ files, OVITO automatically determines a reasonable column-to-property mapping, but you may override it using the
columnskeyword. This can make sense, for example, if the file columns containing the particle coordinates do not follow the standard naming schemex,y, andz(as is the case when importing time-averaged atomic positions computed by LAMMPS, for example).Frame sequences
OVITO automatically detects if the imported file contains multiple data frames (timesteps). Alternatively (and additionally), it is possible to load a sequence of files in the same directory by using the
*wildcard character in the filename. Note that*may appear only once, only in the filename component of the path, and only in place of numeric digits. Furthermore, it is possible to pass an explicit list of file paths to theimport_file()function, which will be loaded as an animatable sequence. All variants can be combined. For example, to load two file sets from different directories as one consecutive sequence:import_file('sim.xyz') # Load all frames contained in the given file import_file('sim.*.xyz') # Load 'sim.0.xyz', 'sim.100.xyz', 'sim.200.xyz', etc. import_file(['sim_a.xyz', 'sim_b.xyz']) # Load an explicit list of snapshot files import_file(['dir_a/sim.*.xyz', 'dir_b/sim.*.xyz']) # Load several file sequences from different directories
The number of frames found in the input file(s) is reported by the
num_framesattribute of the pipeline’sFileSourceYou can step through the frames with afor-loop as follows:from ovito.io import import_file # Import a sequence of files. pipeline = import_file('input/simulation.*.dump') # Loop over all frames of the sequence. for frame_index in range(pipeline.source.num_frames): # Calling FileSource.compute() loads the requested frame # from the sequence into memory and returns the data as a new # DataCollection: data = pipeline.source.compute(frame_index) # The source path and the index of the current frame # are attached as attributes to the data collection: print('Frame source:', data.attributes['SourceFile']) print('Frame index:', data.attributes['SourceFrame']) # Accessing the loaded frame data, e.g the particle positions: print(data.particles.positions[...])
LAMMPS atom style
When loading a LAMMPS data file, the atom style may have to be specified using the
atom_stylekeyword parameter unless the file contains a hint string, which allows OVITO to detect the style automatically. Data files written by the LAMMPSwrite_datacommand or by OVITO contain such a hint, for example. For data files not containing a hint, the atom style must be specified explicitly as in these examples:import_file('full_model.data', atom_style = 'full') import_file('hybrid_model.data', atom_style = 'hybrid', atom_substyles = ('template', 'charge'))
Particle ordering
Particles are read and stored by OVITO in the same order as they are listed in the input file. Some file formats contain unique particle identifiers or tags which allow OVITO to track individual particles over time even if the storage order changes from frame to frame. OVITO will automatically make use of that information where appropriate without touching the original storage order. However, in some situations it may be desirable to explicitly have the particles sorted with respect to the IDs. You can request this reordering by passing the
sort_particles=Trueoption toimport_file(). Note that this option is without effect if the input file contains no particle identifiers.Topology and trajectory files
Some simulation codes write a topology file and separate trajectory file. The former contains only static information like the bonding between atoms, the atom types, etc., which do not change during a simulation run, while the latter stores the varying data (primarily the atomic trajectories). To load such a topology-trajectory pair of files, first read the topology file with the
import_file()function, then insert aLoadTrajectoryModifierinto the returnedPipelineto also load the trajectory data.Explicit file format specification
Normally, OVITO detects the format of the imported file(s) automatically. In rare cases, however, the auto-detection mechanism may fail. Then you can explicitly specify the file format to assume using the
input_formatkeyword parameter. It must be set to one of the following supported format identifiers:"ca","castep/cell","castep/md","cfg","cif","dlpoly","fhi-aims","fhi-aims/log","galamost","gaussian/cube","gro","gsd/hoomd","imd","lammps/data","lammps/dump","lammps/dump/bin","lammps/dump/local","mmcif","netcdf/amber","obj","oxdna","paradis","parcas","pdb","quantumespresso","reaxff/bonds","stl","vasp","vtk/legacy/mesh","vtk/pvd","vtk/vti/grid","vtk/vtm","vtk/vtp/mesh","vtk/vtp/particles","vtk/vts/grid","xsf","xtc","xyz".